DXP D1616 User Manual 75
Read and write series number:
0x6A (Regulate other function)
0x10(write) 0x11(read) series number
0~255(Series number high)
For example: high for 0x12, low for 0x34, then series number is 1234
Read and write communication address (not IP address):
0x6A (Regulate other function)
0x20(write) 0x21(read) Local address
0~99(Local address) 0 means broadcast
address
Local address is default for 0
LOGO Display Parameters Setting:
1/0 Open/Close LOGO display
1/0 Display/Cancel display customer
LOGO
1-10 boot LOGO display time (second)